MODEL LGH-50RVX3-E
25% (Default speed 1)
Air Volume
m3 /h 125
l/s 35
External Static Pressure Pa 10
Temperature Exchange Efficiency
Heating % 75
Cooling % 73
Enthalpy Exchange Efficiency
Heating % 73
Cooling % 65
Specific Fan Power W/(l/s) 0.43
Input Power W 15
Sound Pressure Level dB(A) 17
50% (Default speed 2)
Air Volume
m3 /h 250
l/s 69
External Static Pressure Pa 38
Temperature Exchange Efficiency
Heating % 73.5
Cooling % 71
Enthalpy Exchange Efficiency
Heating % 72
Cooling % 60
Specific Fan Power W/(l/s) 0.49
Input Power W 34
Sound Pressure Level dB(A) 21
75% (Default speed 3)
Air Volume
m3 /h 375
l/s 104
External Static Pressure Pa 85
Temperature Exchange Efficiency
Heating % 71.5
Cooling % 67
Enthalpy Exchange Efficiency
Heating % 69.5
Cooling % 55
Specific Fan Power W/(l/s) 0.78
Input Power W 81
Sound Pressure Level dB(A) 27
100% (Default speed 4)
Air Volume
m3 /h 500
l/s 139
External Static Pressure Pa 150
Temperature Exchange Efficiency
Heating % 70.5
Cooling % 63.5
Enthalpy Exchange Efficiency
Heating % 68.5
Cooling % 51.5
Specific Fan Power W/(l/s) 1.33
Input Power W 185
Sound Pressure Level dB(A) 35
DUCT SIZE mm 200
WEIGHT kg 33
DIMENSIONS WXDXH mm 888 x 1016 x 331
ELECTRICAL POWER SUPPLY 220-240V, 50Hz
Maximum Current A 1.86
FUSE RATING (BS88) – HRC (A) A 6
HEAT EXCHANGER Paper with specially treated Cellulose Membrane
STANDARD FILTER ISO 16890 Coarse 60%*

 

Bypass Ventilation Mode

Stale room air is discharged to outside without passing through the Lossnay core. In spring and autumn when air conditioning is not necessary, the unit operates in bypass ventilation mode.

Heat recovery ventilation

Heat is recovered from the outgoing stale air. This heat is utilised to pre-heat incoming fresh air so your heating system is not required to work as hard to maintain desired room temperature.

Lossnay Ventilation Mode

Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recovered by Lossnay unit.

Filter (Supplied)

Filter cuts pollen and dust for fresh clean air. Replacement part no. P-220F-E. (G3 grade Classification :EN779:2012)

High Efficiency Supply Air filter (Optional)

The supply filter can be upgraded to the high efficency option, a non-washable high efficiency filter (M6 grade Classification :EN779:2012)

Night Purge (Requires PZ-61DR-E controller)

During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set the night purge operation.

Simultaneous air supply and exhaust

Lossnay is the ultimate home ventilation system that provides fresh clean air from outside, while removing both moisture and stale indoor air at the same time. Bringing in fresh air into the house can help improve air quality by lowering the amount of CO2.

  • Air volume 42 l/s (model 15) to 556 l/s (model 200)
  • Clean, fresh air
  • Energy efficient heat recovery
  • Simultaneous air supply and exhaust stale air
  • Heat recovery ventilation
  • Use with Mr Slim and City Multi systems
  • Fresh air without windows open
  • Retains heat
  • Washable supply air filter

Mitsubishi Electric Lossnay Heat Recovery Ventilation LGH-50RVX3-E – Brochure

Description

139 l/s
Free Shipping Business Address Only

air conditioning enquiry