Fujitsu SET-ARTH45KHTA 12.5kW High Static Ducted Air Conditioner System 1 Phase

SKU: SET-ARTH45KHTA / AOTH45KBTA

12.5 kW Cooling | 14.0 kW Heating
SET-ARTH45KHTA 12.5kW High Static Ducted Air Conditioning System | 1 Phase
Includes – Indoor ARTH45KHTA  | Outdoor – AOTH45KBTA
UTY-RNRT – Backlit Touch Panel Wall Controller
5 Years Manufacturer’s Warranty

 



$4,099.00

> > > Compare
Indoor unit ARTH45KHTA
Outdoor unit AOTH45KBTA
Operation Type Reverse Cycle
Power Source
V/Ph/Hz
230 / 1 / 50
Cooling Capacity
kW (Rated (Min – Max))
12.50 (4 – 14)
Heating Capacity
kW (Rated (Min – Max))
14.00 (4.2 – 16.5)
Input Power Cooling
kW (Rated (Max))
3.8 (5.16)
Input Power Heating
kW (Rated (Max))
3.42 (5.22)
EER Cooling
kW/kW
3.29
COP Heating
kW/kW
3.29
Star Rating Cooling
(0-10) (Hot / Average / Cold)
3 / 2.5 / 3
Star Rating Heating
(0-10) (Hot / Average / Cold)
3 / 2.5 / 2
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.612 / 4.403 / 4.635
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.766 / 4.208 / 3.574
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.928 / 5.083 / 5.465
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.764 / 4.41 / 3.901
Running Current
amps (Cooling / Heating)
16.7 / 15
Moisture Removal
l/hr
0.9
Indoor Sound Pressure Cooling
dBA (High / Quiet)
43 / 35
Indoor Sound Pressure Heating
dBA (High / Quiet)
43 / 35
Outdoor Sound Pressure
dBA (Cooling / Heating)
55 / 57
Outdoor Sound Power
dBA
71
Static Pressure Range
PA (Min to Max)
60 to 260
Air Circulation (Indoor – High Fan) Cooling
l/sec
903
Air Circulation (Indoor – High Fan) Heating
l/sec
903
Indoor Unit Dimensions
mm (Height x Width x Depth)
425 x 1250 x 490
Indoor Unit Weight
kg
53.00
Outdoor Unit Dimensions
mm (Height x Width x Depth)
998 x 940 x 320
Outdoor Unit Weight
kg
67.00
Piping Connects
mm Ø (Liquid / Gas)
9.52 / 15.88
Pipe Length
m (Max (Precharged))
50 (30)
Max Height Difference
m
30
Operation Range Cooling
°CDB (Min to Max)
-10 to 50
Operation Range Heating
°CDB (Min to Max)
-15 to 24
Refrigerant Type R32
Refrigerant Amount
g
2,700

The High Static Single Phase R32 range is available in six models, ranging in capacity from 7.1kW to 15.5kW. All models have a maximum guaranteed ambient operating temperature range of up to 50 degrees in cooling mode, have demand response, and are zone system compatible.

 

  • Zone Control
    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.
  • Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    The unit automatically switches between operating modes based on the temperature setting and room temperature.
  • Blue Fin Heat Exchanger
    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.
  • Connectable Distributing Duct
    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.
  • Connectable Fresh Air Duct
    Allows introduction of fresh air to the occupied space.
  • Demand Response
    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.
  • Economy Mode
    Limits the maximum operation current, and performs operation with the power consumption suppressed.
  • Filter Sign
    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
  • On-Off Timer
    ON-OFF timer can be set to operate once every 24 hours.
  • Program Timer
    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.
  • Weekly Timer
    Different ON-OFF times can be set for up to 7 days.
  • In-Built Drain Pump
    The drain pump is in-built into the system.
  • Operating Temperature Range 50°C
    The maximum guaranteed operating temperature range to 50 degrees in cooling mode.
  • Demo Mode
    This function allows the indoor unit to be operated alone at exhibitions and showrooms.
  • Automatic Static Pressure Setting Adjustment
    With this feature, the unit automatically sets the optimal static pressure setting, eliminating the need for the installer to select and set the static pressure setting each time.

Fujitsu SET-ARTH45KHTA 12.5kW High Static Ducted Air Conditioner System 1 Phase – Brochure

High Static R32 Ducted Range

Each model operates with R32 refrigerant, which has a 67 per cent lower ‘Global Warming Potential Factor’, compared to R410A refrigerant, while still maintaining the performance of the unit1. The range features the same lightweight and compact indoor unit chassis design2 and is available in an extended lineup with four new models, totaling 15 models ranging in capacity from 7.1kW to 16kW.

All models have a maximum guaranteed operating temperature range of up to 50 degrees in cooling mode, have Demand Response enabled, and are Zone System compatible.

Description

12.5 kW Cooling
14.0 kW Heating

R32 Refrigerant

air conditioning enquiry