Fully Installed FUJITSU SET-ARTH36KMTAP 10kW Inverter Ducted System Mid Static Slimline 1 Phase | R32

SKU: SET-ARTH36KMTAP-1
  • Based on Single Storey dwelling
  • Installed by Licensed and Arctick Certified Installers
  • Outdoor unit to be placed on Concrete slab | PVC Slab | PVC Mounting Blocks.
  • Weatherproof isolator placed at outdoor.
  • Use of PVC or Colourbond Ducts.
  • Includes electrical circuit up to 15 metres.
  • 5 years full manufacturer warranty on Parts and Labour.
  • Sydney , Central Coast and Newcastle
    *T and C Applies 

FUJITSU SET-ARTH36KMTAP 10kW Inverter Ducted System Mid Static Slimline 1 Phase | R32

Indoor:  ARTH36KMTAP

Outdoor:  AOTH36BTA



$8,000.00

> > > > > Compare
Indoor unit ARTH36KMTAP
Outdoor unit AOTH36KBTA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 240 / 1 / 50
Cooling Capacity kW (Rated (Min – Max)) 10.00 (2.8 – 11.4)
Heating Capacity kW (Rated (Min – Max)) 11.20 (2.7 – 14)
Input Power Cooling kW (Rated (Max)) 3.23 (4.3)
Input Power Heating kW (Rated (Max)) 3.3 (4.5)
EER Cooling kW/kW 3.1914
COP Heating kW/kW 3.7299
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.338 / 4.141 / 4.359
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.568 / 3.815 / 3.201
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.635 / 4.781 / 5.14
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.583 / 4.139 / 3.467
Running Current amps (Cooling / Heating) 13.6 / 13.9
Moisture Removal l/hr 2.9
Indoor Sound Pressure Cooling dBA (High / Quiet) 38 / 27
Indoor Sound Pressure Heating dBA (High / Quiet) 38 / 27
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 53
Outdoor Sound Power dBA 70
Static Pressure Range PA (Min to Max) 50 to 150
Air Circulation (Indoor – High Fan) Cooling l/sec 575
Air Circulation (Indoor – High Fan) Heating l/sec 575
Indoor Unit Dimensions mm (Height x Width x Depth) 240 x 1400 x 700
Indoor Unit Weight kg 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 788 x 940 x 320
Outdoor Unit Weight kg 52.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32
Refrigerant Amount g 1,900

 

The Fujitsu General Mid Static Slimline R32 models are designed with a narrow 240mm high chassis and a built-in drain pump, giving flexibility for the system to be installed in tighter bulkhead and ceiling applications.

  • Zone Control

    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

     

  • Auto Restart

    Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover

    Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger

    Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct

    Connectable Distributing DuctSystems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct

    Connectable Fresh Air DuctAllows introduction of fresh air to the occupied space.

  • Demand Response

    Demand ResponseThis product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Economy Mode

    Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign

    Filter SignSelect appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer

    On-Off TimerON-OFF timer can be set to operate once every 24 hours.

  • Program Timer

    Program TimerThis timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer

    Weekly TimerDifferent ON-OFF times can be set for up to 7 days.

  • controller-feature tick

    In-Built Drain PumpThe drain pump is in-built into the system.

  • Operating Temperature Range 50°CThe maximum guaranteed operating temperature range to 50 degrees in cooling mode.

Ducted air conditioning is surely the ultimate in comfort. The Fujitsu ducted models offer quiet, efficient operation, are easy to maintain, and operated via a wall mounted LCD control that controls all functions of the system.

Description

10.0 kW Cooling
11.2 kW Heating

Blue Fin Heat Exchanger | R32

air conditioning enquiry