Model
|
Set | AS60QEEHRA-SET | ||||
Indoor
|
AS60QEEHRA
|
|||||
Outdoor | 1U60KAEFRA |
Model
|
Cooling | 6.0 (1.6~6.7) | ||||
Heating (H1) | 7.0 (1.8~7.5) | |||||
Heating (H2) | 6.2 | |||||
Cooling | 1.49 (0.41~1.95) | |||||
Heating | 1.73 (0.44~2.50) |
EER/AEER | 4.03/4.01 | |||||
COP/ACOP | 4.05/4.13 | |||||
Star Rating (Hot/Avg/Cold)
|
Cooling | 4.5/3.0/4.0 | ||||
Heating | 2.5/4.5/2.0 | |||||
TCSPF (Hot/Avg/Cold)
|
Residential | 6.369/5.849/6.136 | ||||
Commercial | 8.349/9.583/15.061 | |||||
HSPF (Hot/Avg/Cold)
|
Residential | 4.664/4.228/3.712 | ||||
Commercial | 4.662/4.394/3.961 | |||||
Electrical | ||||||
Rated load amps (RLA)
|
Cooling (Amp) | 6.5 | ||||
Heating (Amp) | 7.6 | |||||
MCA max circuit amps (Amp) | 13.0 | |||||
Breaker size (Amp) | 16 | |||||
Suggested cable size (mm) | 2.5 | |||||
Power cable connection location | Outdoor | |||||
Power supply (Ph/V/Hz) | 1/220-240/50 | |||||
Refrigeration | ||||||
Refrigerant type | R32 | |||||
Refrigerant factory charge (kg) | 1.30 | |||||
Pipe size
|
Liquid line mm | 6.35 (¼”) | ||||
Suction line mm | 12.70 (½”) | |||||
Pipe length (min~max) | 3~25 | |||||
Maximum height difference (m) | 15 | |||||
Pre-charged up to a length (m) | 10 | |||||
Additional refrigerant (grams/meter) | 20 | |||||
Indoor unit | ||||||
Model | AS60QEEHRA | |||||
External dimension – W/D/H (mm) | 345x1106x240 | |||||
Net weight (kg) | 15.5 | |||||
Air flow T/H/M/L | Cooling (L/S) | 345/295/252/210 | ||||
Sound pressure level – SPL (H-L) | 46-27 | |||||
Remote | YR-HJ | |||||
Outdoor unit | ||||||
Model | 1U60KAEFRA | |||||
Net dimension – W/D/H (mm) | 642x816x306 | |||||
Net weight (kg) | 37.5 | |||||
Compressor type | Rotary | |||||
Sound pressure level (dBA) | 54 | |||||
Sound power level (dBA) | 67 | |||||
Outdoor operating temperature range | ||||||
Outdoor (min~max) | Cooling | -10°C ~ 46°C | ||||
Outdoor (min~max) | Heating | -15°C ~ +24°C |