Model: Indoor / Outdoor Unit | PCI-3.0UFA1NQ / PAS-3.0UFASNQ1 |
Power supply (Indoor) V/Ph/Hz | 220~240V / 1Ø / 50Hz |
Power supply (Outdoor) V/Ph/Hz | 220~240V / 1Ø / 50Hz |
Max. power input – Kw | 3.52 |
Max. current input – A | 16.0 |
Cooling Rated Capacity Kw
Cooling Capacity Range[Min~Max] kW |
7.2
2.5~8.6 |
Heating Rated Capacity Kw
Heating Capacity Range[Min~Max] kW |
8.6
3.5~10.4 |
Power comsumption – Cooling kW
Power Heating – Cooling kW |
1.92
2.00 |
AEER Cooling
ACOP Heating |
3.69
4.24 |
TCSPF(Cooling) Commercial / Residential – Hot
TCSPF(Cooling) Commercial / Residential – Average TCSPF(Cooling) Commercial / Residential – Cold |
6.16/5.65
6.29/5.06 6.78/5.28 |
HSPF(Heating) Commercial / Residential – Hot
HSPF(Heating) Commercial / Residential – Average HSPF(Heating) Commercial / Residential – Cold |
5.86/5.83
5.03/4.41 4.04/3.60 |
Indoor Unit – Fan Motor Output W Indoor Unit – Air Flow[Hi2/Hi1/Hi/Med/Lo/SLo] L/S Indoor Unit -Sound Pressure Level [Hi2/Hi1/Hi/Med/Lo/SLo] dB[A] Indoor Unit – Sound Power Level dB[A] Indoor Unit – Dimension [W×H×D] mm Indoor Unit – Packing [W×H×D] mm Indoor Unit – Net/Gross Weight kg Indoor Unit – Drainage water pipe diameter mm
|
60
390/350/310/250 41/39/36/33 52 840×238×840 945×292×945 23/27 VP25 |
Outdoor Unit – Compressor Type Outdoor Unit – Compressor R.L.A Outdoor Unit – Fan Motor F.L.A Outdoor Unit – Fan Motor Output W Outdoor Unit – Air Flow m3/h Outdoor Unit – Sound Pressure Level-Cooling dB[A] Outdoor Unit – Sound Pressure Level-Heating dB[A] Outdoor Unit – Sound Pressure Level-Night dB[A] Outdoor Unit – Sound Power Level dB[A] Outdoor Unit – Throttle Type Outdoor Unit – Dimension [W×H×D] mm Outdoor Unit – Packing [W×H×D] mm Outdoor Unit – Net/Gross Weigh kg
|
KTM240D43UKT
9.3 0.34 80 3290 53 54 51 70 Electronic Expansion Value 900×665×320 1056×717×427 44.0/48.0 |
Refrigerant type/Quantity Type
Refrigerant type/Quantity Charge Kg Refrigerant type/Quantity GWP |
R32
1.4 675 |
Design pressure H/L – MPa | 4.15/2.21 |
Refrigerant pipe – Liquid side/Gas side MM
Refrigerant pipe – Max. pipe length M Refrigerant pipe – Max. Height difference M Refrigerant pipe – Add Refrigerant Amount g/m Refrigerant pipe – Chargeless m |
Φ6.35/Φ12.7
75 30 18 30 |
Guaranteed Temperature Operation Range – Cooling °C | -5~52 |
Guaranteed Temperature Operation Range – Heating °C | -20~15.5 |