VL-350CZPVU-R-E – VL350 Vertical Lossnay Fresh Air Heat Recovery Ventilation
Heat exchange system: Heat Recovery Ventilating System | |||
Heat exchange element material: Sensible Heat Exchanger | |||
Energy Efficiency Class: A+ | |||
Air Duct Configuration: Outside Air and Return Air Ducts located on the right side | |||
General Specifications | |||
Dimensions (WxDxH, mm): 658 x 432 x 623 | |||
Weight: 32 kg | |||
Duct size: 145mm | |||
Power Supply: 220 – 240 V / Single Phase / 50 Hz | |||
Maximum current: 1.32 A | |||
Heat Recovery Ventilation Mode | |||
Fan Power (Fan 1-4): 30 – 50 – 70 – 100% | |||
Running Current (Fan 1-4): 0.18 – 0.31 – 0.52 – 1.08 A | |||
Input Power (Fan 1-4): 19 – 37 – 71 – 155 W | |||
Air Volume (Fan 1-4): 27 – 44 – 62 – 89 l/s | |||
External Static Pressure (Fan 1-4): 14 – 38 – 74 – 150 Pa | |||
Temperature exchange efficiency (Fan 1-4): 90 – 88 – 87 – 85 % | |||
Noise (Fan Speed 1-4): 15 – 19 – 26 – 35 dB |