Rinnai – System Model No. | HSNRT50B | ||
Nominal Capacity | kW | 5.2 | |
Power Supply to Outdoor Unit | V – Ph – Hz | 220~240 – 1 – 50 | |
Recommended Circuit Breaker | A | 16.0 | |
Connectivity | Wi-Fi Enabled | ||
Demand Response Enabling Device | DRED Enabled | ||
Cooling |
Rated Capacity |
kW |
5.20 |
Capacity Range | 1.3-5.70 | ||
Rated Power Input | W | 1280 | |
Rated Current (Range) | A | 5.60 | |
AEER | W/W | 4.04 | |
Star Rating: Hot / Average / Cold | 4.5 / 4.0 / 4.5 | ||
Heating |
Rated Capacity |
kW |
5.2 |
Capacity Range | 1.3-6.3 | ||
Rated Power Input | W | 1260 | |
Rated Current (Range) | A | 5.5 | |
ACOP | W/W | 4.10 | |
Star Rating: Hot / Average / Cold | 3.0 / 2.5 / 2.0 | ||
Maximum Input Power (Cooling / Heating) | W | 2300 | |
Maximum Input Current (Cooling / Heating) | A | 12.0 | |
Suitable Area Coverage (up to 2.6m insulated ceiling) | m2 | 25-34 | |
Moisture Removal | L/h | 1.60 | |
Indoor Unit | HINRT50B | ||
Air Flow (Turbo / Hi / Med / Lo / Min) |
L/s |
292 / 258 / 231 /
197 / 152 |
|
Sound Power Level | dB(A) | 61 | |
Sound Pressure Level @ 1m (Turbo / Hi / Med / Lo / Min) | dB(A) | 49 / 44 / 41 / 36 / 29 | |
Air Swing Louvres | Direction | 4-way swing | |
Dimensions |
Dimension (W x H x D) |
mm |
997 × 316 × 227 |
Packing (W x H x D) | 1067 × 385 × 312 | ||
Net / Gross Weight | kg | 13.0 / 16.0 | |
Operating Range |
Cooling |
˚C |
16°C |
Heating | 32°C | ||
Outdoor Unit | HONRT50B | ||
Sound Power Level |
dB(A) |
60 | |
Sound Pressure Level @ 1m | 44 | ||
Dimensions |
Dimension (W x H x D) |
mm |
900 × 700 × 350 |
Packing (W x H x D) | 1020 × 770 × 430 | ||
Net / Gross Weight | kg | 45 / 49 | |
Refrigerant |
Type | R32 | |
Charged Volume | kg | 1.20 | |
Pipe Size: Liquid / Gas | mm | 6.35 / 12.70 | |
Maximum Pipe Length |
m |
30 | |
Chargeless Length | 10 | ||
Extra Charge for Lengths >10m | g/m | 15 | |
Maximum Vertical Separation | m | 20 | |
Ambient Temperature Limits | Cooling |
˚C |
-15 ~ 52°C |
Heating | -15 ~ 24°C |