Indoor | RAV-SM1103DT-A | ||
Outdoor | RAV-SP1104AT-A2 | ||
Refrigerant Type | R410A | ||
Power Supply | Volts-Phase-Hz | 220-240V -/1/50Hz | |
Cooling | Capacity – Rated | kW | 10.4 |
Capacity – Range (min~max) | kW | 3.3~12.1 | |
Efficiency (rated) | EER | 3.30 | |
Power Input (min~rated~max) | kW | 0.90~3.15~3.99 | |
Operating Current (rated) | A | 14.8 | |
Heating | Capacity – Rated | kW | 11.3 |
Capacity – Range (min~max) | kW | 4.2~17.0 | |
Efficiency (rated) | COP | 4.38 | |
Power Input (min~rated~max) | kW | 0.80~2.58~4.84 | |
Operating Current (rated) | A | 12.1 | |
Indoor Unit | Dimension (HxWxD) | mm | 380x1050x600 |
Net Weight | kg | 57 | |
Airflow Volume | L/s | 693.3 | |
Heating Airflow Volume | L/s | 693.5 | |
Fan Motor Output | W | 600 | |
Sound Pressure (H) at 1m distance | dBA | 49 | |
Sound Power (H) | dBA | 64 | |
Cooling Usable Temperature Range | ˚C | (-15)~43 | |
Heating Usable Temperature Range | ˚C | (-20)~15 | |
Outdoor Unit | Dimension (HxWxD) | mm | 1340x900x320 |
Net Weight | kg | 93 | |
Compressor Type | – | DC Twin Rotary | |
Fan Motor Output | W | 100+100 | |
Cooling Operating Noise (Sound Pressure) (H) at 1m | dBA(@spl) | 49 | |
Cooling Operating Noise (Sound Power) (H) | dBA(@swl) | 66 | |
Heating Operating Noise (Sound Pressure) (H) at 1m | dBA(@spl) | 50 | |
Heating Operating Noise (Sound Power) (H) | dBA(@swl) | 67 | |
Cooling Usable Temperature Range | DB˚C | (-15)/43 | |
Heating Usable Temperature Range | DB˚C | (-20)/15 | |
Pipe Size | Liquid Line ∅ | mm | 9.5 |
Gas Line ∅ | mm | 15.9 | |
Coupler Style | mm | Flaring | |
Drain (Inside Diameter) ∅ | mm | VP25 | |
Maximum Length | m | 75 | |
Chargeless Length | m | 30 | |
Maximum Height Difference | m | 30 |
TOSHIBA RAV-SM1101DTP-A /RAV-SP1104AT-A2 10.4kW High Static Ducted System 1 Phase
10.4kW Cooling – 11.3kw Heating Capacity / High Static Ducted Indoor RAV-SM1103DT-A Outdoor RAV-SP1104AT-A1 Single Phase /
Wired Control with Weekly Timer RBC-AMSU51-ES
Indoor: 298 x 1400 x 750
Outdoor: 1340 x 900 x 320
Wide range of applications
The use of ducts enables air outlets to be installed anywhere on the ceiling. Applications include a wide array of layouts from narrow spaces to polygon rooms.
The benefits
The benefits of Toshiba’s refined design include flexibility in application, low operating sound level, improved air quality and all round comfort. This is as a result of the precise temperature control of Toshiba’s Inverter technology. Plus, all units are high performing as well as energy efficient.
Advantages of Toshiba Air Conditioning Inverter Ducted system
– Quiet operation
– Reverse cycle (heating and cooling)
– Rapid heat and cool functions which increases power temporarily to achieve desired temperature before returning to normal power
– Powerful operation
– 5 year warranty for consumer confidence
– Low maintenance
– R410A non ozone depleting refrigerant
– Easy to install
– Compact unit concealed in ceiling
– DC inverter system, designed to use electricity efficiently and effectively
– Dual controller with the ability to adjust for either controller
– Easy to use controller
Toshiba’s Inverter Ducted systems allow you to air condition your home without having to install the indoor units on your wall, making your home look neat and tidy.
The indoor unit is installed in a confined space and ducts run through the ceiling leading to air outlets in your room. Air is allowed into the room through vents on the ceiling or on the wall.
Description
10.4 kW Cooling
11.3 kW Heating
Includes Weekly Timer Wired Controller