Refrigerant Type R410A
Power Supply Volts-Phase-Hz 220-240V -/1/50Hz
Cooling Capacity – Rated kW 10.4
Capacity – Range (min~max) kW 3.3~12.1
Efficiency (rated) EER 3.30
Power Input (min~rated~max) kW 0.90~3.15~3.99
Operating Current (rated) A 14.8
Heating Capacity – Rated kW 11.3
Capacity – Range (min~max) kW 4.2~17.0
Efficiency (rated) COP 4.38
Power Input (min~rated~max) kW 0.80~2.58~4.84
Operating Current (rated) A 12.1
Indoor Unit Dimension (HxWxD) mm 380x1050x600
Net Weight kg 57
Airflow Volume L/s 693.3
Heating Airflow Volume L/s 693.5
Fan Motor Output W 600
Sound Pressure (H) at 1m distance dBA 49
Sound Power (H) dBA 64
Cooling Usable Temperature Range ˚C (-15)~43
Heating Usable Temperature Range ˚C (-20)~15
Outdoor Unit Dimension (HxWxD) mm 1340x900x320
Net Weight kg 93
Compressor Type DC Twin Rotary
Fan Motor Output W 100+100
Cooling Operating Noise (Sound Pressure) (H) at 1m dBA(@spl) 49
Cooling Operating Noise (Sound Power) (H) dBA(@swl) 66
Heating Operating Noise (Sound Pressure) (H) at 1m dBA(@spl) 50
Heating Operating Noise (Sound Power) (H) dBA(@swl) 67
Cooling Usable Temperature Range DB˚C (-15)/43
Heating Usable Temperature Range DB˚C (-20)/15
Pipe Size Liquid Line ∅ mm 9.5
Gas Line ∅ mm 15.9
Coupler Style mm Flaring
Drain (Inside Diameter) ∅ mm VP25
Maximum Length m 75
Chargeless Length m 30
Maximum Height Difference m 30
Wide range of applications

The use of ducts enables air outlets to be installed anywhere on the ceiling. Applications include a wide array of layouts from narrow spaces to polygon rooms.

The benefits

The benefits of Toshiba’s refined design include flexibility in application, low operating sound level, improved air quality and all round comfort. This is as a result of the precise temperature control of Toshiba’s Inverter technology. Plus, all units are high performing as well as energy efficient.

Advantages of Toshiba Air Conditioning Inverter Ducted system

– Quiet operation
– Reverse cycle (heating and cooling)
– Rapid heat and cool functions which increases power temporarily to achieve desired temperature before returning to normal power
– Powerful operation
– 5 year warranty for consumer confidence
– Low maintenance
– R410A non ozone depleting refrigerant
– Easy to install
– Compact unit concealed in ceiling
– DC inverter system, designed to use electricity efficiently and effectively
– Dual controller with the ability to adjust for either controller
– Easy to use controller

Toshiba’s Inverter Ducted systems allow you to air condition your home without having to install the indoor units on your wall, making your home look neat and tidy.

The indoor unit is installed in a confined space and ducts run through the ceiling leading to air outlets in your room.  Air is allowed into the room through vents on the ceiling or on the wall.

Description

10.4 kW Cooling
11.3 kW Heating
Includes Weekly Timer Wired Controller 

air conditioning enquiry